Advanced Performance UniBloc Balances
Faster Response and Higher Stability
Faster Response and Higher Stability
Series | W Series | ||||||
---|---|---|---|---|---|---|---|
Model | AP225W | AP135W | AP125WD | AP225WD | AP124W | AP224W | AP324W |
Capacity | 220g | 135 g | 120 g / 52g | 220 g / 102g | 120 g | 220 g | 320 g |
Minimum Display | 0.01 mg | 0.01 mg / 0.1 mg | 0.1 mg | ||||
Calibration Weight | Built-in *1 | ||||||
External Calibration Weight Range for Span Calibration | 95 to 220.00090 g (200g) |
45 to 135.009 g (100 g) |
95 to 120.0090 g (100 g) |
95 to 220.009 g (200 g) |
45 to 120.009 g (100 g) |
95 to 220.009 g (200 g) |
95 to 320.009 g (300 g) |
Repeatability (Standard deviation) |
0.015mg
(to 20g)
0.03mg (to 100g)
0.05mg (to Minimum Weight)
|
0.05 mg | 0.1 mg / 0.02 mg | 0.1 mg / 0.05 mg | 0.1 mg | 0.15 mg | |
Minimum Weight *2 | 20 mg | 30 mg | 200 mg | ||||
Linearity *2 | ±0.1 mg | ±0.1 mg | ±0.2 mg /±0.05 mg | ±0.2 mg /±0.1 mg | ±0.2 mg | ±0.3 mg | |
Response Time for race Measurements *3 | 2 sec. | ||||||
Response Time *4 | 8 sec. | 2 sec. / 8 sec. | 2 sec. | ||||
USB Host (Type A) | Included | ||||||
USB Device (Type B) | Included | ||||||
Recipe Compounding | Included | ||||||
HPLC Buffer Solution Preparation | Included | ||||||
mol Conversion Function | Included | ||||||
Sample (Concentration) Preparation | Included | ||||||
Inspection Support Function | Included | ||||||
Clock-CAL | Included | ||||||
Ionizer | Optional | ||||||
Operating Temperature/Humidity Range | 5 to 40°C 20 to 85% *5 | ||||||
Sensitivity Stability Against Temperature Range | ±2 ppm/°C (10 to 30°C) | ||||||
Pan Size | ø91 mm | ||||||
Body Dimensions | Approx. 212(W) x 411(D) x 345(H)mm (power supply unit included) |
Approx. 212(W) x 367(D) x 345(H)mm | |||||
Weight | Approx. 7.9 kg | Approx. 7.0 kg | |||||
Display | OEL display (dot matrix) | ||||||
Input/Output Terminal | RS-232C (D-sub9P plug) USB host (Type A) USB device (Type B) Ionizer |
Series | W Series | Y Series | ||||
---|---|---|---|---|---|---|
Model | AP124X | AP224X | AP324X | AP124Y | AP224Y | AP324Y |
Capacity | 120 g | 220 g | 320 g | 120 g | 220 g | 320 g |
Minimum Display | 0.1 mg | |||||
Calibration Weight | Built-in | No | ||||
External Calibration Weight Range for Span Calibration | 45 to 120.009 g (100 g) |
95 to 220.009 g (200 g) |
95 to 320.009 g (300 g) |
45 to 120.009 g (100 g) |
95 to 220.009 g (200 g) |
95 to 320.009 g (300 g) |
Repeatability (Standard deviation) | 0.1 mg | 0.15 mg | 0.1 mg | 0.15 mg | ||
Minimum Weight *2 | 200 mg | |||||
Linearity*2 | ±0.2 mg | ±0.3 mg | ±0.2 mg | ±0.3 mg | ||
Response Time for race Measurements *3 | 2 sec. | |||||
Response Time *4 | 2 sec. | |||||
USB Host (Type A) | Not Included | |||||
USB Device (Type B) | Included | |||||
Recipe Compounding | Not Included | |||||
HPLC Buffer Solution Preparation | Not Included | |||||
mol Conversion Function | Included | Not Included | ||||
Sample (Concentration) Preparation | Not Included | |||||
Inspection Support Function | Included | Not Included | ||||
Clock-CAL | Included | Not Included | ||||
Ionizer | Optional | Not Included | ||||
Operating Temperature/Humidity Range | 5 to 40°C 20 to 85% *5 | |||||
Sensitivity Stability Against Temperature Range | ±2 ppm/°C (10 to 30°C) | |||||
Pan Size | Φ91 mm | |||||
Body Dimensions | Approx. 212 (W) x 367 (D) x 345 (H) mm | |||||
Weight | Approx. 7.0 kg | Approx. 6.5 kg | ||||
Display | OEL display (dot matrix) | |||||
Input/Output Terminal | RS-232C (D-sub9P plug) USB device (Type B) Ionizer |
RS-232C (D-sub9P plug) USB device (Type B) |
*2 Be compliant with USP Chapter 41. This is the tested value by the weight of the balance’s capacity of 5% (or 5 grams’ weight). In the case of the AP225W, the results are for tests carried out with the optional internal windbreak plate applied. The minimum weight value is affected by the installation environment, so it is necessary to measure it in the actual environment of use.
*3 The response time for displaying 90% of the added sample amount value in trace measurements (from 1mg)
*4 The response time value is typical.
*5 Non-condensing.