SHIMADZU AP Series Micro Analytical Balances
SKU : #PD1312-SHIM
AP Series - Specs
W-AD ex Series
W ex Series
W-AD Series
W Series
X Series, Y Series
W-AD ex Series Micro Analytical Balance
(Equipped Standard with Smart Automatic Doors and Touchless Sensors)
Model | AP225W-AD ex | AP135W-AD ex | AP225WD-AD ex | AP125WD-AD ex |
|---|---|---|---|---|
Capacity | 220g | 135g | 220g / 102g | 120g / 52g |
Minimum Display | 0.01mg | 0.1mg / 0.01mg | ||
Calibration Weight | Built-in (*1) | |||
External Calibration Weight Range for Span Calibration (Recommended weight value) | 95 to 220.00090g (200g) | 45 to 135.00090g (100g) | 95 to 220.00090g (200g) | 45 to 120.00090g (100g) |
Repeatability (at weighing capacity) | 0.03mg | 0.02mg | 0.1mg / 0.02mg | |
Repeatability | 0.0065mg (Approx. 5% load) | |||
Minimum Weight (*2, *3) | 13mg (*2) | |||
Linearity (*2) | ±0.1mg | ±0.2mg / ±0.1mg | ±0.2mg / ±0.05mg | |
Response Time for Trace Measurements (*4, *5) | 2 sec. | |||
Response Time (*5) | 8 sec. | 2 sec. / 8 sec. | ||
USB Host (Type A) | ○ | |||
USB Device (Type B) | ○ | |||
Recipe Compounding | ○ | |||
HPLC Buffer Solution Preparation | ○ | |||
mol Conversion Function | ○ | |||
Sample (Concentration) Preparation | ○ | |||
Inspection Support Function | ○ | |||
Clock-CAL | ○ | |||
Automatic Doors | ○ | |||
Touchless Sensors | ○ | |||
Adjustable Windbreak Plate | ○ | |||
Ionizer | ○ | |||
Operational Temperature / Humidity Range | 5 to 40℃ at 20 to 85% RH (*6) | |||
Sensitivity Stability Against Temperature Range | ±2ppm / ℃ (10~30℃) | |||
Pan Size | Approx. 91 mm dia. | |||
Body Dimensions | Approx. W215 × D411 × H346 mm (power supply unit included) | |||
Weight | Approx. 9.7kg | |||
Display | OEL display (dot matrix) | |||
Rated Electric Power Supply | DC12V 0.5A | |||
Input Power Supply | For EU type approval models: AC100V - 240V 0.48A 50/60 Hz (*7) For other models: AC100V - 240V 0.7A 50/60 Hz (*7) | |||
Input / Output Terminal | RS-232C (D-Sub 9P plug) USB host (Type A) USB device (Type B) Ionizer | |||
*1 Minimum display 0.01 mg models provide two internal weights as standard.
*2 Based on our shipping inspection conditions.
*3 Compliant with the Japanese Pharmacopoeia, USP 41 and Ph.Eur.2.1.7. Minimum weight value is met at the Shimadzu Corporation factory using weights equal to approximately 5 % of the weighing capacity. This value is affected by the installation environment, so it is necessary to measure it in the actual environment of use.
*4 The response time for displaying 90 % of the added sample amount value in trace measurements (from 1 mg).
*5 The response time value is typical.
*6 Non-condensing.
*7 The Input Power Supply may change without notice.
W ex Series Micro Analytical Balance
Model | AP225W ex | AP135W ex | AP225WD ex | AP125WD ex |
|---|---|---|---|---|
Capacity | 220g | 135g | 120g / 52g | 220g / 102g |
Minimum Display | 0.01mg | 0.1mg / 0.01mg | ||
Calibration Weight | Built-in (*1) | |||
External Calibration Weight Range for Span Calibration (Recommended weight value) | 95 to 220.00090g (200g) | 45 to 135.00090g (100g) | 45 to 120.00090g (100g) | 95 to 220.00090g (200g) |
Repeatability (at weighing capacity) | 0.03mg | 0.02mg | 0.1mg / 0.02mg | |
Repeatability | 0.0065mg (approx. 5 % load) | |||
Minimum Weight (*2, *3) | 13mg | |||
Linearity (*2) | ±0.1mg | ±0.2mg / ±0.1mg | ±0.2mg / ±0.05mg | |
Response Time for Trace Measurements (*4, *5) | 2 sec. | |||
Response Time (*5) | 8 sec. | 2 sec. / 8 sec. | ||
USB Host (Type A) | ○ | |||
USB Device (Type B) | ○ | |||
Recipe Compounding | ○ | |||
HPLC Buffer Solution Preparation | ○ | |||
mol Conversion Function | ○ | |||
Sample (Concentration) Preparation | ○ | |||
Inspection Support Function | ○ | |||
Clock-CAL | ○ | |||
Internal Windbreak Plate | ○ | |||
Ionizer (optional) | ○ | |||
Operational Temperature / Humidity Range | 5 to 40℃ at 20 to 85% RH (*6) | |||
Sensitivity Stability Against Temperature Range | ±2ppm/℃ (10~30℃) | |||
Pan Size | Approx. 91 mm dia. | |||
Body Dimensions | Approx. W213 × D411 × H345 mm (power supply unit included) | |||
Weight | Approx. 7.9 kg | |||
Display | OEL display (dot matrix) | |||
Rated Electric Power Supply | DC12V 0.3A | |||
Input Power Supply | For EU type approval models: AC100V - 240V 0.32 - 0.19 A 50/60 Hz (*7) For other models: AC100 V - 240 V 0.7 A 50/60 Hz (*7) | |||
Input / Output Terminal | RS-232C (D-Sub 9P plug) USB host (Type A) USB device (Type B) Ionizer | |||
*1 Minimum display 0.01 mg models provide two internal weights as standard.
*2 Based on our shipping inspection conditions.
*3 Compliant with the Japanese Pharmacopoeia, USP 41 and Ph.Eur.2.1.7. Minimum weight value is met at the Shimadzu Corporation factory using weights equal to approximately 5 % of the weighing capacity. This value is affected by the installation environment, so it is necessary to measure it in the actual environment of use.
*4 The response time for displaying 90 % of the added sample amount value in trace measurements (from 1 mg).
*5 The response time value is typical.
*6 Non-condensing.
*7 The Input Power Supply may change without notice.
W-AD Series Micro Analytical Balance
(Equipped Standard with Smart Automatic Doors and Touchless Sensors)
Model | AP225W-AD | AP135W-AD | AP225WD-AD | AP125WD-AD | AP324W-AD | AP224W-AD | |
|---|---|---|---|---|---|---|---|
Capacity | 220g | 135g | 220g / 102g | 120g / 52g | 320g | 220g | |
Minimum Display | 0.01mg | 0.1mg / 0.01mg | 0.1mg | ||||
Calibration Weight | Built-in (*1) | ||||||
External Calibration Weight Range for Span Calibration (Recommended weight value) | 95 to 220.00090g (200g) | 45 to 135.00090g (100g) | 95 to 220.00090g (200g) | 45 to 120.00090g (100g) | 95 to 320.0090g (300g) | 95 to 220.0090g (200g) | |
Repeatability (at weighing capacity) | 0.015mg (up to 20g) 0.03mg (up to 100g) 0.05mg (up to 220g) | 0.05mg | 0.1mg / 0.05mg | 0.1mg / 0.02mg | 0.15mg | 0.1mg | |
Repeatability | 0.01mg (approx. 5% load) | 0.1mg (approx. 5% load) | |||||
Minimum Weight (*2, *3) | 20mg | 200mg | |||||
Linearity (*2) | ±0.1mg | ±0.2mg / ±0.1mg | ±0.2mg / ±0.05mg | ±0.3mg | ±0.2mg | ||
Response Time for Trace Measurements (*4, *5) | 2 sec. | ||||||
Response Time (*5) | 8 sec. | 2 sec. / 8 sec. | 2 sec. | ||||
USB Host (Type A) | ○ | ||||||
USB Device (Type B) | ○ | ||||||
Recipe Compounding | ○ | ||||||
HPLC Buffer Solution Preparation | ○ | ||||||
mol Conversion Function | ○ | ||||||
Sample (Concentration) Preparation | ○ | ||||||
Inspection Support Function | ○ | ||||||
Clock-CAL | ○ | ||||||
Automatic Doors | ○ | ||||||
Touchless Sensors | ○ | ||||||
Adjustable Windbreak Plate | ○ | - | |||||
Ionizer | ○ | ||||||
Operational Temperature / Humidity Range | 5 to 40℃ at 20 to 85% RH (*6) | ||||||
Sensitivity Stability Against Temperature Range | ±2ppm / ℃ (10~30℃) | ||||||
Pan Size | Approx. 91 mm dia. | ||||||
Body Dimensions | Approx. W215 × D411 × H346 mm (power supply unit included) | Approx. W215 × D367 × H346 mm | |||||
Weight | Approx. 9.7kg | Approx. 8.6kg | |||||
Display | OEL display (dot matrix) | ||||||
Rated Electric Power Supply | DC12V 0.5A | ||||||
Input Power Supply | For EU type approval models: AC100V - 240V 0.48A 50/60 Hz (*7) For other models: AC100V - 240V 0.7A 50/60 Hz (*7) | ||||||
Input / Output Terminal | RS-232C (D-Sub 9P plug) USB host (Type A) USB device (Type B) Ionizer | ||||||
*1 Minimum display 0.01 mg models provide two internal weights as standard.
*2 Based on our shipping inspection conditions.
*3 Compliant with the Japanese Pharmacopoeia, USP 41 and Ph.Eur.2.1.7. Minimum weight value is met at the Shimadzu Corporation factory using weights equal to approximately 5 % of the weighing capacity. This value is affected by the installation environment, so it is necessary to measure it in the actual environment of use.
*4 The response time for displaying 90 % of the added sample amount value in trace measurements (from 1 mg).
*5 The response time value is typical.
*6 Non-condensing.
*7 The Input Power Supply may change without notice.
W Series Micro Analytical Balance
Model | AP225W | AP135W | AP125WD | AP225WD | AP124W | AP224W | AP324W |
|---|---|---|---|---|---|---|---|
Capacity | 220g | 135g | 120g / 52g | 220g / 102g | 120g | 220g | 320g |
Minimum Display | 0.01mg | 0.1mg / 0.01mg | 0.1mg | ||||
Calibration Weight | Built-in (*1) | ||||||
External Calibration Weight Range for Span Calibration (Recommended weight value) | 95 to 220.00090g (200g) | 45 to 135.00090g (100g) | 45 to 120.00090g (100g) | 95 to 220.00090g (200g) | 45 to 120.0090g (100g) | 95 to 220.0090g (200g) | 95 to 320.0090g (300g) |
Repeatability (at weighing capacity) | 0.015mg (up to 20g) 0.03mg (up to 100g) 0.05mg (up to 220g) | 0.05mg | 0.1mg / 0.02mg | 0.1mg / 0.05mg | 0.1mg | 0.15mg | |
Repeatability | 0.01mg (approx. 5% load) | 0.1mg (approx. 5% load) | |||||
Minimum Weight (*2, *3) | 20mg | 200mg | |||||
Linearity (*2) | ±0.1mg | ±0.2mg / ±0.05mg | ±0.2mg / ±0.1mg | ±0.2mg | ±0.3mg | ||
Response Time for Trace Measurements (*4, *5) | 2 sec. | ||||||
Response Time (*5) | 8 sec. | 2 sec. / 8 sec. | 2 sec. | ||||
USB Host (Type A) | ○ | ||||||
USB Device (Type B) | ○ | ||||||
Recipe Compounding | ○ | ||||||
HPLC Buffer Solution Preparation | ○ | ||||||
mol Conversion Function | ○ | ||||||
Sample (Concentration) Preparation | ○ | ||||||
Inspection Support Function | ○ | ||||||
Clock-CAL | ○ | ||||||
Internal Windbreak Plate | ○ | ○ (optional) | |||||
Ionizer (optional) | ○ | ||||||
Operational Temperature / Humidity Range | 5 to 40℃ at 20 to 85% RH (*6) | ||||||
Sensitivity Stability Against Temperature Range | ±2ppm/℃ (10~30℃) | ||||||
Pan Size | Approx. 91 mm dia. | ||||||
Body Dimensions | Approx. W213 × D411 × H345 mm (power supply unit included) | Approx. W213 × D367 × H345 mm | |||||
Weight | Approx. 7.9 kg | Approx. 7.0 kg | |||||
Display | OEL display (dot matrix) | ||||||
Rated Electric Power Supply | DC12V 0.3A | ||||||
Input Power Supply | For EU type approval models: AC100V - 240V 0.32 - 0.19 A 50/60 Hz (*7) For other models: AC100 V - 240 V 0.7 A 50/60 Hz (*7) | ||||||
Input / Output Terminal | RS-232C (D-Sub 9P plug) USB host (Type A) USB device (Type B) Ionizer | ||||||
*1 Minimum display 0.01 mg models provide two internal weights as standard.
*2 Based on our shipping inspection conditions.
*3 Compliant with the Japanese Pharmacopoeia, USP 41 and Ph.Eur.2.1.7. Minimum weight value is met at the Shimadzu Corporation factory using weights equal to approximately 5 % of the weighing capacity. This value is affected by the installation environment, so it is necessary to measure it in the actual environment of use.
*4 The response time for displaying 90 % of the added sample amount value in trace measurements (from 1 mg).
*5 The response time value is typical.
*6 Non-condensing.
*7 The Input Power Supply may change without notice.
X Series / Y Series Micro Analytical Balance
Series | X Series | Y Series | ||||
|---|---|---|---|---|---|---|
Model | AP324X | AP224X | AP124X | AP324Y | AP224Y | AP124Y |
Capacity | 320g | 220g | 120g | 320g | 220g | 120g |
Minimum Display | 0.1mg | |||||
Calibration Weight | Built-in | None | ||||
External Calibration Weight Range for Span Calibration (Recommended weight value) | 95 to 320.0090g (300g) | 95 to 220.0090g (200g) | 45 to 120.0090g (100g) | 95 to 320.0090g (300g) | 95 to 220.0090g (200g) | 45 to 120.0090g (100g) |
Repeatability (at weighing capacity) | 0.15mg | 0.1mg | 0.15mg | 0.1mg | ||
Repeatability | 0.1mg (approx. 5% load) | |||||
Minimum Weight (*1) | 200mg | |||||
Linearity | ±0.3mg | ±0.2mg | ±0.3mg | ±0.2mg | ||
Response Time for Trace Measurements (*2, *3) | 2 sec. | |||||
Response Time (*3) | 2 sec. | |||||
USB Host (Type A) | - | |||||
USB Device (Type B) | ○ | |||||
Recipe Compounding | - | |||||
HPLC Buffer Solution Preparation | - | |||||
mol Conversion Function | ○ | - | ||||
Sample (Concentration) Preparation | - | |||||
Inspection Support Function | ○ | - | ||||
Clock-CAL | ○ | - | ||||
Ionizer | ○ | - | ||||
Operational Temperature / Humidity Range | 5~40℃ 20 to 85% (*4) | |||||
Sensitivity Stability Against Temperature Range | ±2ppm/℃ (10 to 30℃) | |||||
Pan Size | Approx. 91 mm dia. | |||||
Body Dimensions | Approx. W213 × D367 × H345 mm | |||||
Weight | Approx. 7.0 kg | Approx. 6.5 kg | ||||
Display | OEL display (dot matrix) | |||||
Rated Electric Power Supply | DC12V 0.3A | |||||
Power Supply Input | For EU type approval models: AC100V - 240V 0.32 - 0.19 A 50/60 Hz (*5) For other models: AC100 V - 240 V 0.7 A 50/60 Hz (*5) | |||||
Input / Output Terminal | RS-232C (D-Sub 9P plug) USB device (Type B) Ionizer | RS-232C (D-Sub 9P plug) USB device (Type B) | ||||
*1 Compliant with the Japanese Pharmacopoeia, USP 41 and Ph.Eur.2.1.7. Minimum weight value is met at the Shimadzu Corporation factory using weights equal to approximately 5 % of the weighing capacity. This value is affected by the installation environment, so it is necessary to measure it in the actual environment of use.
*2 The response time for displaying 90 % of the added sample amount value in trace measurements (from 1 mg).
*3 The response time value is typical.
*4 Non-condensing.
*5 The Input Power Supply may change without notice.
Shimadzu Electronic Balances General Catalog [ PDF / 11.41MB ] Click Here